| Directory |
Trade Leads |
Rated |
Visits |
Date |
Images |
Circuit Breaker
 |
F360 residual current circuit breakerF360 F362 F364 series residual current circuit breaker is in accordance with standards of VDE 0664, CEE27 and BS4293 etc, applying to the circuit of AC 50/60Hz,240V single phase, 415V three phases
Number of poles2P,4P Rated Current(In)25,32,40,63A Rated residual operating current(In)10,30,100,300,500mA Rated Voltage(Un)AC 230(240) / 400(415)V Residual operating current scope0.5In~In Residual cu... |
0 (#0) |
93 |
2010.12.13 |
 |
Circuit Breaker
 |
electrical productApplication
Residual Current Device(RCD) FIN is in conformity with the standard of IEC61008.
It can cut off the fault circuit immediately on the occasion of shock hazard or earth le
Specification
Type FIN25 FIN40 FIN63 FIN100
Rated current In(A) 25 40 63 100
Rated operating current for earth leakage In(A) 0.03,0.1,0.3,0.5 0.1,0.3,0.5
Rated non-oper... |
0 (#0) |
81 |
2010.12.13 |
 |
Circuit Breaker
 |
circuit breakers manufacturer hs at best-electrical comTheRCCB residual current circuit breaker item is in accordance with standards of VDE 0664,CEE27 and BS4293 etc,applying to the circuit of AC 50/60Hz,240V single phase,415V three pha
The RCCB is in conformity with the standard of IEC61008. The RCCB can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk. Thus, it is suitable to avoid the... |
0 (#0) |
154 |
2010.04.06 |
 |
Circuit Breaker
|
1-320W solar panel
Our company is a professional supplier of every kinds of solar panels from Ningbo of China. We can supply quality products with ver
Our company, HK TIANZE INDUSTRY CO.,LTD, is a professional supplier of solar panels from Ningbo of China. We can produce 1-300W solar panels, both mono and poly are available. With certifications of C... |
0 (#0) |
281 |
2010.03.07 |
 |
Circuit Breaker
|
C45N Mini Circuit Breaker C45N series circuit breaker is used in lighting distribution system or motor distribution system for protec
C45N series circuit breaker is used in lighting distribution system or motor distribution system for protecting overl-oad and shortcircuit in the system. The product is neote-ric in structure, ligh... |
0 (#0) |
326 |
2010.01.12 |
 |
Circuit Breaker
|
Mini Circuit BreakerThey have protective function as shortage as overload, and are used in lighting distribution system in industy, commerce and dwelling, and protect fractional electric notors. And they also have many m
They have protective function as shortage as overload, and are used in lighting distribution system in industy, commerce and dwelling, and protect fractional electric notors. And they also have many m... |
0 (#0) |
384 |
2008.09.17 |
 |
Circuit Breaker
|
AC ContactorFeatures: 1) Circuit: AC 50Hz / 60Hz2) Rated working voltage: 660V / 380V3) Rated working current up to 95A4) Can switch on and off a remote circuit, protecting it from eventual
Features:
1) Circuit: AC 50Hz / 60Hz
2) Rated working voltage: 660V / 380V
3) Rated working current up to 95A
4) Can switch on and off a remote circuit, protecting it from... |
0 (#0) |
351 |
2008.09.17 |
 |
Circuit Breaker
 |
JVM2-63... |
0 (#0) |
325 |
2008.07.26 |
 |
Circuit Breaker
 |
TKM9 Molded Case Circuit Breaker- ABB MCCB#Application
*Type: TKM9-125E, TKM9-125S, TKM9-160S, TKM9-160H, TKM9-250S, TKM9-250M, TKM9-400S, TKM9-400M, TKM9-400H, TKM9-630M, TKM9-630H, TKM9-800S, TKM9-800M, TKM9-800H
*Rated cu... |
0 (#0) |
686 |
2008.04.14 |
 |
Circuit Breaker
 |
Moulded Case Circuit Breaker JMB(ABB)(MCCB)JMB(ABB) series moulded case circuit breaker, it's applicable circuit of AC 50HZ/60HZ, rated insulation voltage 660V, rated operating voltage under AC 660V, 250(DC), rated operating current 10A-80
Frame current: 125A, 250A, 400A, 630A, 800A, 1250A.
Rated Current: 6A-1250A
Pole no.: 3, 4 pole
... |
0 (#0) |
961 |
2008.03.25 |
 |
Circuit Breaker
 |
residual current circuit breaker with over-current protectionThe products provide protection against earth leakage faults,overloads,short circuits and overvoltage in commercial and domestic installation.
The RCBO incorporates a residual current
JVL 6:
Standard:
GB16917
IEC61009
... |
0 (#0) |
785 |
2007.10.30 |
 |
Circuit Breaker
 |
residual current circuit breaker JVL1-63
TUV S CB CCC... |
0 (#0) |
535 |
2007.10.12 |
 |
Circuit Breaker
 |
F360 Residual Current Circuit BreakerF360 Residual Current Circuit BreakerThe item is in accordance with standards of IEC1008,VDE 0664,CEE27 and BS4293 etc.,applying to the circuit of AC 50/60Hz,240V single phase,415V three phases an
AEG MCB UNELEC C45 mcb aeg BKN DX MCB AEG AEG MCB UNELEC C45 NC-100H BKN BKM DX BH BH-P BH-N MG GE AEG PLS6 L7 C65 DZ47 DPN ,C60N, MY MY MW W40 BH-D6 K101 DPX MB H6 S250 E4CB 5SX 5SU MEM SX1-G3 SX2... |
0 (#0) |
650 |
2007.10.08 |
 |
Circuit Breaker
 |
ID Residual Current Circuit Breaker MSN: cncming@hotmail.com hotline: +86-13757778950ID Residual Current Circuit BreakerThe ID RCCB????s residual current devices provide the functions isolation,switching and earth leakage protection of electrical circuits.They have a residual
DZ47LE DPNLE F360 ID NFIN... |
0 (#0) |
628 |
2007.10.08 |
 |
Circuit Breaker
 |
L7 Series Circuit Breaker MSN: cncming@hotmail.com hotline: +86-13757778950L7 Series Circuit BreakerThe L7 series MCB belongs to the advanced level of the world.They have the characteristics of small size,high sensitivity long using life and strong protective function fo
PLS6 L7 C65 DZ47 DPN ,C60N, MY MY MW W40 BH-D6 K101 DPX MB H6 S250 E4CB 5SX 5SU MEM SX1-G3 SX2-G3 TQL TQC BHC FN NF CM1 DZ15 DZ10 DZ47LE DPNLE F360 ID NFIN +86-13757778950 LC1-D,3TB,3TF RCCB,RCBO,... |
0 (#0) |
737 |
2007.10.08 |
 |
Circuit Breaker
 |
NT-58 Mini Circuit Breaker MSN: cncming@hotmail.com hotline: +86-13757778950NT-58 Mini Circuit BreakerThe circuit breaker is used as a protection switch for power supplying a circuit with AC 50/60Hz,voltage 220V,current up to 32A.It has inherent overload protection functi
UNELEC C45 NC-100H BKN BKM DX BH BH-P BH-N MG GE AEG PLS6 L7 C65 DZ47 DPN ,C60N, MY MY MW W40 BH-D6 K101 DPX MB H6 S250 E4CB 5SX 5SU MEM SX1-G3 SX2-G3 TQL TQC BHC FN NF CM1 DZ15 DZ10 DZ47LE DPNLE ... |
0 (#0) |
568 |
2007.10.08 |
 |
Circuit Breaker
 |
S101 Screw Circuit Breaker MSN: cncming@hotmail.com hotline: +86-13757778950S101 Screw Circuit BreakerThe circuit breaker are suitable used in AC and DC 32A below electric circuit of 50Hz,up to 380V and up to DC 250V respectively,for protction of electrical circuits
MCB AEG AEG MCB UNELEC C45 mcb aeg BKN DX MCB AEG AEG MCB UNELEC C45 NC-100H BKN BKM DX BH BH-P BH-N MG GE AEG PLS6 L7 C65 DZ47 DPN ,C60N, MY MY MW W40 BH-D6 K101 DPX MB H6 S250 E4CB 5SX 5SU MEM SX... |
0 (#0) |
621 |
2007.10.08 |
 |
Circuit Breaker
 |
DZ47 DPN ,C60N, MY MY MW W40 BH-D6 K101 DPX MB H6 S250 E4CB 5SX 5SU MEM SX1-G3 SX2-G3 TQL TQC BHC
DZ47 DPN ,C60N, MY MY MW W40 BH-D6 K101 DPX MB H6 S250 E4CB 5SX 5SU MEM SX1-G3 SX2-G3 TQL TQC BHC FN NF CM1 DZ15 DZ10 DZ47LE DPNLE F360 ID NFIN +86-13757778950 LC1-D,3TB,3TF RCCB,RCBO,RCD, Meter,... |
0 (#0) |
627 |
2007.10.08 |
 |
Circuit Breaker
 |
residual current circuit breakerResidual Current Circuit Breaker provide the function of isolation switching and earth leakage protection of electric
High short-circuit current withstand capacity.
Applicable to terminal and pin/fork busbar connection
Contact position indication equipped with finger protected connection terminals.
| 0 (#0) |
646 |
2007.09.28 |
 |
Circuit Breaker
 |
mini circuit breakerthese product are applicable to circuit with rated voltage up 400V AC, rated frequency 50/60Hz and for protection and control of circuit against overload and short circuit in commercial, hous
JVM16-63:
Elegant appearance and cover and handle in arc shape making the operation comfortable.
Its transparent cover is designed to carry label.
In case of overload to p... |
0 (#0) |
627 |
2007.09.28 |
 |
Circuit Breaker
 |
C45The breaker is suitable to be applied in the power distribution system for illumination (corresponding to model C) and motor (corresponding to model D). The circuit breaker is characterized by elegant
Main technical parameters:
1) Rated current of frame class (inm): 63A
2) Rated voltage (Ue): 50 / 60Hz, 230 / 400V
3) Rated current (In): 1, 2, 4, 6, 10, 16, 20, 25, 32, 40, 50... |
0 (#0) |
771 |
2007.07.05 |
 |
Circuit Breaker
 |
3UV
Aeg mcb MCB AEG AEG MCB UNELEC C45 mcb aeg BKN BH BH-P BH-N MG GE AEG L7 C65 DZ47 DPN ,C60N, MY MY MW W40 BH-D6 K101 DPX MB H6 E4CB 5SX MEM SX1-G3 SX2-G3 NF CM1 DZ15 DZ47LE DPNLE F360ID NFIN +86-... |
0 (#0) |
823 |
2007.04.28 |
 |
Circuit Breaker
 |
RCCB
Aeg mcb MCB AEG AEG MCB UNELEC C45 mcb aeg BKN BH BH-P BH-N MG GE AEG L7 C65 DZ47 DPN ,C60N, MY MY MW W40 BH-D6 K101 DPX MB H6 E4CB 5SX MEM SX1-G3 SX2-G3 NF CM1 DZ15 DZ47LE DPNLE F360ID NFIN +86-... |
0 (#0) |
851 |
2007.04.28 |
 |
Circuit Breaker
 |
MCB AM8
Aeg mcb MCB AEG AEG MCB UNELEC C45 mcb aeg BKN BH BH-P BH-N MG GE AEG L7 C65 DZ47 DPN ,C60N, MY MY MW W40 BH-D6 K101 DPX MB H6 E4CB 5SX MEM SX1-G3 SX2-G3 NF CM1 DZ15 DZ47LE DPNLE F360ID NFIN +86-... |
0 (#0) |
661 |
2007.04.28 |
 |
Circuit Breaker
 |
mcb C45
Aeg mcb MCB AEG AEG MCB UNELEC C45 mcb aeg BKN BH BH-P BH-N MG GE AEG L7 C65 DZ47 DPN ,C60N, MY MY MW W40 BH-D6 K101 DPX MB H6 E4CB 5SX MEM SX1-G3 SX2-G3 NF CM1 DZ15 DZ47LE DPNLE F360ID NFIN +86-... |
0 (#0) |
643 |
2007.04.28 |
 |