Advertisements
Trademetro.net Trade Leads / Construction and Real Estate / Bath and Toilet Appliances


Consisting of : French Vernet wax element, thermostatic cartridge, body made from solid cast brass( brass material from South Korea) gravity casting.

 


TECHNICAL DATA
1. The ideal working pressure: 0.1-0.5Mpa
(A protection value shall be used if the supply pressure exceeds 0.5Mpa)
2. Cold Water supply temperature: 4-29 oC
Hot water supply temperature: 55-85oC
(Working temperature in use from 55- 65oC is suggested
3. Outlet water temperature range: 20- 49 oC
4. Set the safety temperautre at 38oC
5. Cold water supply failure test
If the cold water supply fails, the volume of outlet water collected during the first 5±0.5s shall be less than 200ml and the temperature of outlet water shall be less than 49oC.
If the volume of water collected during the first five seconds >200ml, the outlet temperature shall not exceed 42oC. The volume of water collected during the second collection period of 30±0.5s shall be less than 300ml. The temperature of the water outlet shall be at 38±2oC after restoration of the cold water supply.
6. Outlet water temperature stability (See Fig.1)
When inlet water temperature keeps stable and either of the inlet pressure for cold and hot water varies by 20%, within the initial 5s at the outlet, the temperature spikes exceeding +3 oC from the set temperature shall not exceed 1.5s and temperature spikes exceeding -5oC from the set temperature shall not exceed 1s for each spike. When inlet water pressure keeps stable and the temperature for hot water supply increases from 60 oC to 73 oC at the speed about 3oC/min, the temperature differential from outlet temperature to set temperature shall not exceed 2oC.
7. Supply water pressure vs outlet water temperature (See Fig.2)
8. Supply water pressure vs outlet flow rate(See Fig.3)
9. Complies with Standards: ASSE1016-2005, ASMEA112.18.1-2005/CSA B125.1-05, EN1111, AS4032.1, QB2806-2006


  Advertisements  
   


Posted by Alina Fang
e-MailContact company
Company
Phenix Home Products Limited
Address Unit 302, Block 6, No.36, Nanwanbei Road,
City & ZIP
Zhuhai City, Guangdong Province 519000
Country
China
Phone
For registered Members only.
Fax
For registered Members only.
Key Customers / Clientele thermostatic faucet
Company Profile Leading the trend in thermostatic and pressure balance technology in the world, our company offers high-quality thermostatic faucets including thermostatic faucets for shower, thermostatic faucets for shower and bath, thermostatic and presure balance faucets to the world market. Our operation principle is: Quality, sustainibility, long term relationship based on trust and confidence. We hope to establish close relations with interested professionals from all over the world on the basis of equality and mutual benefit.
URLFor registered Members only.
Rating (0 reviews)
Popular tags
Keywords (seperated by comma)Thermostatic Faucet
Product SpecificationsConsisting of : French Vernet wax element, thermostatic cartridge, body made from solid cast brass( brass material from South Korea) gravity casting.

TECHNICAL DATA
1. The ideal working pressure: 0.1-0.5Mpa
(A protection value shall be used if the supply pressure exceeds 0.5Mpa)
2. Cold Water supply temperature: 4-29 oC
Hot water supply temperature: 55-85oC
(Working temperature in use from 55- 65oC is suggested
3. Outlet water temperature range: 20- 49 oC
4. Set the safety temperautre at 38oC
5. Cold water supply failure test
If the cold water supply fails, the volume of outlet water collected during the first 5±0.5s shall be less than 200ml and the temperature of outlet water shall be less than 49oC.
If the volume of water collected during the first five seconds >200ml, the outlet temperature shall not exceed 42oC. The volume of water collected during the second collection period of 30±0.5s shall be less than 300ml. The temperature of the water outlet shall be at 38±2oC after restoration of the cold water supply.
6. Outlet water temperature stability (See Fig.1)
When inlet water temperature keeps stable and either of the inlet pressure for cold and hot water varies by 20%, within the initial 5s at the outlet, the temperature spikes exceeding +3 oC from the set temperature shall not exceed 1.5s and temperature spikes exceeding -5oC from the set temperature shall not exceed 1s for each spike. When inlet water pressure keeps stable and the temperature for hot water supply increases from 60 oC to 73 oC at the speed about 3oC/min, the temperature differential from outlet temperature to set temperature shall not exceed 2oC.
7. Supply water pressure vs outlet water temperature (See Fig.2)
8. Supply water pressure vs outlet flow rate(See Fig.3)
9. Complies with Standards: ASSE1016-2005, ASMEA112.18.1-2005/CSA B125.1-05, EN1111, AS4032.1, QB2806-2006
Industry CategoryFaucets
Quality/Safety CertificationsCE
Delivery Lead Time45 daygs
Payment & Price TermsFOB Shenzhen
My OffersQuality, Service, Innovation
Product Portfolio / Other ProductsFaucets
CustomersN/A
Detailed Company Introduction2007
FOB Price & Port1million usd
Packaging DetailsN/A
Our TeamN/A
Web SiteFor registered Members only.

View Reviews and Comments

 Leave a comment *login-required
     
Title  
 
Comment  
 
Code  
    
   

Product Details
Product id 207421
Visits  380
Date 2007.09.23
 

Execution time:0.10419702529907